3. Operating Pressure

Check the cut-out pressure of your water pump. Is it below the lifting pressure of the relief valve fitted to the C-Warm heater? If it's below 2.0 bar then you can use the standard water heaters.

See page 14.

A water pressure of 2 bar (2kg/sq cm) is ample for most domestic purposes. Water usage is likely to increase at higher pressures. The pressure switch on a small pressurised water pump typically cuts in at about 0.7 bar (10 p.s.i.) and out at about 1.4 bar (20 p.s.i) The relief valve set to to lift at 2.5 bar remains closed.

Pumps with cut-out pressure at or above 2.5 bar can generate enough pressure to lift the relief valve, protecting the storage heater from excessive pressure but leading to continuous loss of water. If a pump cut-out pressure of 2.5 bar or more is essential, a storage heater with a higher pressure rating is required. C-Warm hihg pressure models are rated for use at pressures up to 3.5 bar (51 p.s.i.) with matching relief valves.

WARNING
ON NO ACCOUNT SHOULD A HIGH PRESSURE RELIEF VALVE BE FITTED
IN A STANDARD PRESSURE STORAGE HEATER

 
C-Warm Index

 

 

Refer to Page

 

1. Water Capacity

 

1, 13

 

2. Space Available

 

1

 

3. Vertical or Horizontal

 

1, 8, 9, 13, 14

 

4. Single or Twin Coil

 

2, 13

 

5. Standard or High Pressure

 

3, 13

 

6. Fixing the Heater in place

 

8, 9, 10

 

7. Connecting the Pipework

 

11

 

8. Electric immersion Heater

 

2, 7, 11, 16

 

9. Controlling stored water Temperature

 

4, 5, 15, 16

 

10. Dealing with thermal expansion

 

6

 

11. F.A.Q

 

12


Tek-Tanks Ltd
The Old Stables
West End Farm
Colthouse Lane
Upper Froyle
Hampshire
GU34 4JR
England

Tel: +44 (0) 1420 520830
Fax: +44 (0) 1420 520840

A Tek-Group Company

©Tek-Tanks Ltd 2005

Website developed by HolloGraphics Ltd
sitemap